CAV25

CAV 25 VERTICAL DISCHARGE FAN – MOBILE MOUNT

Designed by Dowse Engineering for ducted exhaust and extraction applications. The Cyclo Vertical range of exhaust fans use axial flow and centrifugal design to provide high pressure characteristic stable over a wide range of airflow. The design allows for lower RPM and subsequent lower energy and noise levels.

Performance Image

Technical Data

Model No. Fan Speed Rev/Min K.W Amps Volts Approx Noise Level @ 3mtr (dBA) Motor Shaft mm IP Rating
CAV-25-184-SP 1400 0.18 1.35 240 53 13 55

Dimensions

Dimensions Image
A 530 mm
B 380 mm
C 50 mm
D 45 mm
E 260 mm
F 310 mm

Typical Industries & Applications :
Hospitality | Commercial Kitchens, Food Trucks, Mobile Food Containers
Manufacturing | Welding, Powder Coating, Spray Painting, Glue Works, Fibre Glassing
Warehousing / Office | Ablution Block, Heat Extraction
Extraction of Heat, Toxic Gas and Hazardous Gas options

Description Vertical Exhaust Fan – Mobile Mount
Model CAV 25
Int. Flange Dia 260 mm
Fixing Vertical, Roof Mounted
Features High performing, robust and light weight
Locally owned and manufactured in Melbourne (Australia) since 1947
EPA Compliant, Australian & NZ Standards Compliant
Impeller Each impeller is individually designed and manufactured to precise specifications for maximum airflow at high pressure
Hand crafted and balanced
Aluminium alloy
Mixed flow type impellers (axial flow and centrifugal design)
Enclosure Galvanized steel casing and waste resistant motor enclosures
Motor mounted outside airstream
Supplied with associated flanges
Motor Typical Kulthorn Electric
Phase(s) Single Phase Only
Custom Motors Hazard Area Motors
– Ex ‘d’ Flame, Ex ‘e’ Increased Safety, Ex ‘n’ Non-Sparking, Dust Ignition Proof, Bush Fire Code Compliant
Circuit Breaker Separate Current rated circuit breaker (IEC/EN 60947 approved) must be installed between the motor and building power supply.
Circuit breaker overload should be set to suit motor’s amp draw.
Control Option(s) 5A Variable Speed Switch (Available)
Weight Approx. 16.5 kilograms
Installation Fan Unit: Roof Plumber, Canopy Maintenance / Installer
Electrical Connections: Licensed electrician
Transport Top load only
Ensure impeller has not been exposed to wet weather.
Any water inside the motor housing can damage the motor.

* All performance curves are approximates * Please contact our consultants for accurate data.

Enquire Now

  

Related Product